Environmental conditions
Temperature range: -40 °C/+150 °C
Materials
Insulating body: PA, V-2 according to UL94
Contact tab: CuSn, silver-plated
Connectable conductors for IDT area
Construction: discrete conductor, notched flat cable 5.0 mm
Section min.: 1,0 mm²
Section max.: 1,5 mm²
Insulation diameter: ≤ 3,0 mm
Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 10.5 A (Tamb 120 °C)
Rated voltage: 250 V AC