Environmental conditions
Temperature range: -40 °C/+125 °C – 3626 (S...V...)
-40 °C/+130 °C – 3626 M08(S...V...)
-40 °C/+130 °C – 3626 M20(S...V...) *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PA, V-2 according to UL94 – 3626 (S...V...)
PA, V-2 according to UL94 – 3626 M08(S...V...)
PA, V-0 according to UL94 – 3626 M20(S...V...) *1
Contact spring: CuSn, tin-plated – 3626 (M...S...)
CuSn, silver-plated – 3626 (M...S...)V01
1) M08: component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)
M20: material halogen-free, GWFI 850 °C (0.4 mm), GWIT 775 °C (0.4 mm)
Mechanical data
Mating with: tab contact 6.3 mm x 0.8 mm according to DIN 46244
Insertion force/contact: ≤ 4,0 N *1
Withdrawal force/contact: ≥ 1,0 N *2
1) measured with a polished flat steel pin, nominal thickness 0.8 mm
2) measured with a polished flat steel pin, nominal thickness 0.8 mm
Connectable conductors for IDT area
Construction: discrete conductor, notched flat cable 5.0 mm
Section min.: 0,22 mm²
Section max.: 1,0 mm²
Insulation diameter: ≤ 2,5 mm
Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 10 A (0.75 mm², Tamb 70 °C) – 3626 (M…V…)
4 A (0.38 mm², Tamb 70 °C) – 3626 (M…)S01(V…)
Rated voltage: 250 V AC *1
1) according to IEC 60664/DIN EN 60664, CTI UL classification according to ANSI/UL 746A