Environmental conditions
Temperature range: -40 °C/+120 °C *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PA GF, V-0 according to UL94 – 3541-1 M13S01 *1
Contact pin: CuSn, tin-plated
1) component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)
Connectable conductors for IDT area
Construction: discrete conductor, notched flat cable 2.5 mm
Section max.: 0.50 mm²
Insulation diameter: ≤ 2.2 mm
Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.
Electrical data (at Tamb 20 °C)
Rated current: 4 A (Tamb 60 °C, VDE)
2 A (Tamb 110 °C, VDE)
4 A (0.34 mm², cULus)
2 A (0.25 mm², cULus)
Rated voltage: 32 V AC *1
1) according to IEC 60664/DIN EN 60664, CTI UL classification according to ANSI/UL 746A