Environmental conditions
Temperature range: -40 °C/+130 °C *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PBT, V-0 according to UL94 – 3511-1 (S...V...)
PA, V-2 according to UL94 – 3511-1 M12(S...V...) *1
Contact spring: CuSn, tin-plated – 3511-1 (M...S...)
CuSn, tin-plated (Sn/Ag), 2-9 poles – 3511-1 (M...S...)V03
CuSn, pre-nickel and gold-plated – 3511-1 (M...S...)V102
1) M12: component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)
Mechanical data
Mating with: printed circuit board 1.5 ± 0.14 mm
Insertion force/contact: ≤ 4,0 N
Withdrawal force/contact: ≥ 0,5 N
Connectable conductors for IDT area
Construction: flat cable 2.5 mm
Section min.: 0,14 mm²
Section max.: 0,38 mm²
Insulation diameter: ≤ 1,6 mm
Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 4 A (Tamb 60 °C)
2 A (Tamb 100 °C)
Rated voltage: 250 V AC