Environmental conditions
Temperature range: -25 °C/+80 °C
Materials
Insulating body: PC, V-2 according to UL94
Contact: CuSn, pre-nickel and gold-plated in mating area
Schirmung: CuZn, nickel-plated
Mechanical data
Mating cycles: 1000
Insertion force: ≤ 36.3 N
Withdrawal force: ≥ 89.3 N
Connectable conductors for piercing area
Section: AWG 26
Construction: flat cable 2.55 mm x 10.55 ± 0.2 mm or
round cable Ø 6.0 mm ± 0.2 mm
Stripping length cable jacket: 12 mm
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 20 mΩ
Rated current: 2 A
Rated voltage: 250 V AC
Rated impulse voltage: 1 kV