Environmental conditions
Temperature range: -40 °C/+85 °C
Materials
Insulating body: PA GF, V-0 according to UL94
Contact bush: CuZn, silver-plated and flash gold-plated (3-8 poles)
CuZn, pre-nickel and gold-plated (12 poles)
Sleeve: PC, HB according to UL94
Strain relief: steel, nickel-plated
Housing: CuZn, nickel-plated
Bend protection sleeve: TPE
Screw: steel, nickel-plated
Mechanical data
Insertion force/contact: ≤ 5.0 N *1
Withdrawal force/contact: ≥ 1.2 N (3-8 poles)
≥ 0.9 N (12 poles) *2
Protection class: IP40 *3
1) measured with a polished steel pin, nominal thickness 1.5 mm (1.0 mm with 12 poles)
2) measured with a polished steel pin, nominal thickness 1.5 mm (1.0 mm with 12 poles)
3) according to IEC DIN EN 60529, only in locked condition with an appropriate counterpart
Connectable conductors for solder area
Section: ≤ 0.75 mm² (AWG 20)
(3-8 poles)
≤ 0.25 mm² (AWG 24)
(12 poles)
Cable diameter: 4–6 mm
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 5 A (Tamb 40 °C, 3-8 poles)
3 A (Tamb 40 °C, 12 poles)
Rated voltage: with pollution degree 1:
300 V (versions 30, 40, 50/6, 60, 70)
100 V (versions 50, 71, 80, 81)
160 V (Polbild 120)
with pollution degree 2:
250 V (versions 30, 40)
32 V (versions 50, 71, 80, 81)
160 V (versions 50/6, 60, 70, 120)
Rated impulse voltage: 1500 V (versions 30, 40, 50/6, 60, 70, 120)
500 V (versions 50, 71, 80, 81)