Environmental conditions
Temperature range: -40 °C/+130 °C *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PA, V-2 according to UL94 *1
Contact spring: CuNiSi, silver-plated
1) component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)
Mechanical data
Mating with: tab contact 6.3 mm x 0.8 mm according to DIN 46244
Insertion force: ≤ 95 N *1
Withdrawal force: ≥ 45 N *2
1) measured at a mating pair of connectors 3690 02/3695 02
2) measured at a mating pair of connectors 3690 02/3695 02
Connectable conductors for IDT area
Construction: discrete conductor
Section max.: AWG 14 (2,5 mm²)
Insulation diameter: 3,6 mm
Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 25 A (Tamb 85 °C)
Rated voltage: 500 V AC