Environmental conditions
Temperature range: -40 °C/+125 °C – 3623 01 V01
-40 °C/+130 °C – 3623 01 M08V01
-40 °C/+130 °C – 3623 01 M20V01 *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PA, V-2 according to UL94 – 3623 01 (V01)
PA, V-2 according to UL94 – 3623 01 M08(V01)
PA, V-0 according to UL94 – 3623 01 M20(V01) *1
Contact spring: CuSn, silver-plated
1) M08: component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)
M20: material halogen-free, GWFI 960 °C (0.75 mm), GWIT 775 °C (0.75 mm)
Mechanical data
Mating with: tab contact 6.3 mm x 0.8 mm according to DIN 46244
Insertion force: ≤ 40 N *1
Withdrawal force: ≥ 15 N *2
1) measured with a polished flat steel pin, nominal thickness 0.8 mm
2) measured with a polished flat steel pin, nominal thickness 0.8 mm
Connectable conductors for IDT area
Construction: discrete conductor, notched flat cable 5.0 mm
Section min.: 0.5 mm²
Section max.: 0.9 mm²
Insulation diameter: ≤ 2.5 mm
Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 10 A (0.75 mm², Tamb 70 °C)
Rated voltage: 250 V AC