Environmental conditions
Temperature range: -40 °C/+125 °C – 3623 (S...)
-40 °C/+130 °C – 3623 M08(S...)
-40 °C/+130 °C – 3623 M20(S...) *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PA, V-2 according to UL94 – 3623 (S...)
PA, V-2 according to UL94 – 3623 M08(S...)
PA, V-0 according to UL94 – 3623 M20(S...) *1
Contact spring: CuSn, tin-plated
1) M08: component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)
M20: material halogen-free, GWFI 960 °C (0.75 mm), GWIT 775 °C (0.75 mm)
Mechanical data
Mating with: tab contact 6.3 mm x 0.8 mm according to DIN 46244
Insertion force/contact: ≤ 4,0 N
Withdrawal force/contact: ≥ 1,0 N
Connectable conductors for IDT area
Construction: discrete conductor, notched flat cable 5.0 mm
Section min.: 0,22 mm²
Section max.: 1 mm²
Insulation diameter: ≤ 2,5 mm
Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 10 A (0,75 mm², Tamb 70 °C) – 3623 (M…)
5 A (0,38 mm², Tamb 70 °C) – 3623 (M…)S01
Rated voltage: 250 V AC