Environmental conditions
Temperature range: -40 °C/+130 °C *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PBT GF, V-0 according to UL94 – 3570
PA, V-2 according to UL94 – 3570 M09 *1
Contact spring: Cu alloy, silver-plated – 3570
Cu alloy, tin-plated – 3570 V03
1) M09: component glow wire resistant (GWT 750 °C), testing acc. to IEC 60695-2-11, assessment acc. to IEC 60335-1 (flame < 2 s)
Mechanical data
Mating with: printed circuit board 1.5 ± 0.14 mm
Insertion force/contact: ≤ 4.0 N
Withdrawal force/contact: ≥ 0.5 N
Connectable conductors for IDT area
Construction: discrete conductor, notched flat cable 5.0 mm
Section min.: 0,35 mm²
Section max.: 0,82 mm²
Insulation diameter: ≤ 2,5 mm
Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 3570:
6 A (Tamb 70 °C)
10 A (indirect mating, 2-5 poles)
3570 V03:
6 A (Tamb 70 °C, max. 4 poles under load)
Rated voltage: 400 V AC