Environmental conditions
Temperature range: -40 °C/+130 °C *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PA, V-0 according to UL94 *1
Contact spring: CuSn, tin-plated
(with 10 or more poles with contact variant V214, CuSn, tin-plated, with lubricant)
1) material halogen-free, GWFI 850 °C, GWIT 775 °C
Mechanical data
Insertion force/contact: ≤ 4,0 N
Withdrawal force/contact: ≥ 0,5 N
Retaining force/locking: ≥ 6,0 N *1
1) measured with a polished steel gauge, nominal thickness 1.5 mm
Connectable conductors for IDT area
Construction: discrete conductor, notched flat cable 2.5 mm
Section min.: 0,35 mm²
Section max.: 0,38 mm²
Insulation diameter: ≤ 1,6 mm
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 4 A (Tamb 60 °C)
2 A (Tamb 100 °C)
Rated voltage: 80 V AC