Environmental conditions
Temperature range: -40 °C/+130 °C *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PBT, V-0 nach UL94 *1
Contact spring: CuSn, silver-plated
1) material halogen-free, GWFI 850 °C (0,40 mm), GWIT 775 °C (0,40 mm)
Mechanical data
Mating with: printed circuit board 1.6 ± 0.14 mm
Insertion force/contact: ≤ 3 N
Withdrawal force/contact: ≥ 3 N
Retaining force/locking: ≥ 90 N
Connectable conductors for IDT area
Construction: discrete conductor, notched flat cable 2.5 mm
Section min.: 0,22 mm²
Section max.: 0,38 mm²
Insulation diameter: ≤ 1.6 mm
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 4 A (Tamb 85 °C)
Rated voltage: 50 V AC *1
1) according to IEC 60664/DIN EN 60664, CTI UL classification according to ANSI/UL 746A