Environmental conditions
Temperature range: -25 °C/+100 °C *1
1) upper limit temperature (insulating body) RTI (electrical) of the UL Yellow Card
Materials
Insulating body: PBT, V-0 according to UL94
Contact spring: CuSn, tin-plated
Mechanical data
Insertion force/contact: ≤ 5 N *1
Withdrawal force/contact: ≥ 2 N *2
1) measured with a polished square steel pin, nominal thickness 1.0 mm
2) measured with a polished square steel pin, nominal thickness 1.0 mm
Connectable conductors for IDT area
Construction: discrete conductor, notched flat cable 5.08 mm
Section min.: 0,20 mm²
Section max.: 0,75 mm²
Insulation diameter: ≤ 2,5 mm
Note: Most products are available with different IDT contact variants. Please note the section Approved Cables below.
Electrical data (at Tamb 20 °C)
Contact resistance: ≤ 5 mΩ
Rated current: 6 A (0,75 mm², TU 70 °C)
Rated voltage: 250 V AC *1
1) according to IEC 60664/DIN EN 60664, CTI UL classification according to ANSI/UL 746A